Skip to main navigation Skip to search Skip to main content

Application of the field and laboratory emission cell "FLEC" - performance study, intercomparison study, and case study of damaged linoleum in an office

Research output: Contribution to journal › Journal article › Research › peer-review

Abstract

The Field and Laboratory Emission Cell (FLEC) has been tested and evaluated for qualitative and quantitative emission testing of volatile organic compounds (VOCs) from building products. An air supply control unit has been developed and its performance is reported in the range of 100 to 500 mllmin airflows. The recovery in the FLEC has been tested with a new performance test kit with dodecane and 2-ethylhexanol, respectively. Additionally, five VOCs emitted from a liquid floor wax were measured in the FLEC and in a small climate chamber. The first order rate constants (k1) and the initial emission rates (R0) obtained from the time versus concentration data measured over 24 hours proved to be comparable. The application of FLEC in a complaint case of malodorous linoleum in an office building showed that artificial wetting of the linoleum had a marked influence on the qualitative offgassing of odorous VOCs such as fatty acids, glycol ethers, and 2-decenal.
Original languageEnglish
JournalIndoor Air
Volume5
Issue number3
Pages (from-to)196-203
Number of pages8
ISSN0905-6947
DOIs
Publication statusPublished - 1995

Fingerprint

Dive into the research topics of 'Application of the field and laboratory emission cell "FLEC" - performance study, intercomparison study, and case study of damaged linoleum in an office'. Together they form a unique fingerprint.

Cite this