TY - JOUR
T1 - Perceived loading and muscle activity during hip strengthening exercises: comparison of elastic resistance and machine exercises
AU - Brandt, M.
AU - Jakobsen, Markus Due
AU - Thorborg, K.
AU - Sundstrup, Emil Haals
AU - Andersen, Lars Louis
N1 - SUBMISSIONYEAR:2013
PY - 2013
Y1 - 2013
N2 - Decreased hip muscle strength is frequently reported in patients with hip injury or pathology. Furthermore, soccer players suffering from groin injury show decreased strength of hip muscles. Estimating 10-repetition maximum can be time-consuming and difficult, thus, using the Borg category rating 10 scale (Borg CR10 scale) can be useful for estimating the intensity of exercise. The aims of this study were 1) to investigate the feasibility of the use of the Borg CR10 scale for rating strength training intensity of the hip abductor and hip adductor muscles, and 2) to compare hip muscle activity during hip abduction and hip adduction exercises using elastic resistance and isotonic machines, using electromyography (EMG). The results of this study show that the Borg CR10 scale can be a useful tool for estimating intensity levels during resistance training of the hip adductor and hip abductor muscles. Although elastic resistance and exercise machine seem equally effective for recruiting muscle activity of the hip adductors, the elastic resistance condition was able to demonstrate greater muscle recruitment than the exercise machine during hip abduction.
AB - Decreased hip muscle strength is frequently reported in patients with hip injury or pathology. Furthermore, soccer players suffering from groin injury show decreased strength of hip muscles. Estimating 10-repetition maximum can be time-consuming and difficult, thus, using the Borg category rating 10 scale (Borg CR10 scale) can be useful for estimating the intensity of exercise. The aims of this study were 1) to investigate the feasibility of the use of the Borg CR10 scale for rating strength training intensity of the hip abductor and hip adductor muscles, and 2) to compare hip muscle activity during hip abduction and hip adduction exercises using elastic resistance and isotonic machines, using electromyography (EMG). The results of this study show that the Borg CR10 scale can be a useful tool for estimating intensity levels during resistance training of the hip adductor and hip abductor muscles. Although elastic resistance and exercise machine seem equally effective for recruiting muscle activity of the hip adductors, the elastic resistance condition was able to demonstrate greater muscle recruitment than the exercise machine during hip abduction.
M3 - Journal article
VL - 8
SP - 811
EP - 819
JO - International Journal of Sports Physical Therapy
JF - International Journal of Sports Physical Therapy
IS - 6
ER -